automotive-hardware-safety
Calculate and verify diagnostic coverage for safety mechanisms Covers 4 topics across hardware-safety domain.
Skill by pangzhenying2025
Chalk Labs
Need help deploying automotive-hardware-safety?
Chalk Labs sets up agents like this inside real teams: connected to your tools, tested on your data, with a human in the loop where it matters.
Install
Works with Claude Code, Claude apps, Codex, Cursor, Gemini CLI, GitHub Copilot, VS Code, OpenCode, Goose, Windsurf. Read the repository before you give any tool access to your data.
npx agentmarket install skill/pangzhenying2025-automotive-hardware-safety
Asks which of your tools to add it to (Claude Code, Codex, Cursor, VS Code, Windsurf, Gemini CLI, Claude Desktop) and shows the change first. See https://agentmart.dev/cli.
Get the weekly diff
The weekly diff: one email a week with new agent tools, notable updates and grade changes, plus security alerts for tools you follow. Double opt-in, one-click unsubscribe.
About
Use cases: testing
Reviews
Write a reviewNo reviews yet. Installed it? Reviews come from verified installers only. How reviews work
Permissions
What this skill can do and what it asks for, from its SKILL.md. Checked Oct 25, 2026.
- Tools
- No tools found
- Secrets
- None asked for
- Install scripts
- None found
Network hosts it talks to 1
codeload.github.com· found in install command
Files it touches
~/.claude/skills/automotive-hardware-safety
What's inside
- Skill name
automotive-hardware-safety- Description
- Calculate and verify diagnostic coverage for safety mechanisms Covers 4 topics across hardware-safety domain. Includes 4 skill files covering .
- License
- MIT
- Instructions
- 387 lines in SKILL.md · view on GitHub
Files (1)
- SKILL.md
SKILL.md (first lines)
# Automotive Hardware Safety 4 skill files covering hardware-safety domain for automotive software engineering. ## Instructions ### Diagnostic Coverage Analysis You are an expert in diagnostic coverage analysis per ISO 26262. **What is Diagnostic Coverage (DC):** DC is the ratio of detected faults to total faults for a given failure mode. **Formula:** DC = λ_detected / (λ_detected + λ_undetected) Where: - λ_detected: Failure rate detected by safety mechanism - λ_undetected: Residual failure rate (not detected) **Diagnostic Coverage Levels (ISO 26262-5 Table 6):** - DC = 0%: None (no diagnostic) - DC < 60%: Low - 60% ≤ DC < 90%: Medium - 90% ≤ DC < 99%: High - DC ≥ 99%: Very High **Sources of Diagnostic Coverage:** **1. Hardware Diagnostics:** - Plausibility checks (range, gradient, correlation) - Redundancy and voting (dual sensors, triple modular redundancy) - Self-tests (BIST, RAM/ROM tests) - Watchdog timers - Memory protection (ECC, parity, CRC) - Voltage/temperature monitoring **2. Software Diagnostics:** - Control flow monitoring - Data integrity checks (checksums, CRCs) - Alive counters - Sequence monitoring - Logical execution time monitoring **Diagnostic Coverage by Mechanism:** | Safety Mechanism | Typical DC | ISO 26262 Reference | |------------------|-----------|---------------------| | Plausibility check (range) | 60-70% | Part 5, Annex D | | Dual sensor with voting | 90-95% | Part 5, Annex D | | Triple modular redundancy | 99%+ | Part 5, Annex D | | Watchdog timer | 90-95% | Part 6, Annex B | | ECC memory | 95-99% | Part 5, Annex D | | CRC on communication | 99%+ | Part 6, Annex B | **Calculating Overall DC:** For multiple diagnostics on same element: DC_total = 1 - Π(1 - DC_i) for independent diagnostics Example: - Plausibility check: DC1 = 70% - Redundant sensor: DC2 = 90% - DC_total = 1 - (1 - 0.7)(1 - 0.9) = 1 - (0.3)(0.1) = 1 - 0.03 = 97% **Verification of DC:** DC must be verified, not just claimed. Methods: - Fault injection testing (software/hardware) - Formal verification - Analysis (for well-established mechanisms) **Fault Injection:** - Inject faults into hardware (voltage glitch, bit flip) - Verify safety mechanism detects fault - Calculate observed DC from test results **Example:** - Inject 100 faults into RAM - ECC detects 97 faults - Observed DC = 97/100 = 97% **Impact on ASIL Metrics:** High DC enables: - Lower PMHF (fewer residual faults) - Higher SPFM (more single-point faults detected) - Possible ASIL decomposition (if DC ≥ 99%) **DC in ASIL Decomposition:** To decompose ASIL D(D) → ASIL B(D) + ASIL B(D): - Safety mechanism must have DC ≥ 99% - Both elements developed to ASIL B - Dependent failure analysis (DFA) required ### HSI - Hardware-Software Interface Safety You are an expert in Hardware-Software Interface (HSI) safety per ISO 26262. **What is HSI:** HSI is the boundary between hardware and software elements where they interact. Critical for safety as errors at this interface can bypass both HW and SW safety mechanisms. **ISO 26262 Requirements:** - Part 4 (System): 7.4.7 - Interface specification - Part 5 (Hardware): 7.4.7 - HSI requirements from hardware perspective - Part 6 (Software): 7.4.7 - HSI requirements from software perspective **Common HSI Elements:** **1. Memory-Mapped I/O:** - Peripheral registers (GPIO, CAN, ADC, PWM) - Configuration registers - Status/control registers **2. Interrupts:** - Interrupt vectors
From pangzhenying2025/hermes-automotive-skills, MIT.
Signals
- Stars
- 10
- Forks
- 2
- Open issues
- 0
- Last commit (this folder)
- May 19, 2026 (6 months ago)
From GitHub (fetched Oct 24, 2026).
Details
- License
- MIT
- First seen
- Oct 24, 2026
- Last checked
- Oct 24, 2026
- Source
- GitHubgithub-graphql
Done for you
Rather not set it up yourself?
Chalk Labs scopes, builds and runs agents for your team: the task audit, the eval harness, the integrations and the weekly ops report. Fixed scope, priced before we start.
See how we build AI agents →Read the case studies
Chalk Labs is a two-founder AI and growth studio. We build AI agents, CRMs and MVPs for Web3 and AI companies, and have shipped 50+ product and token launches.
- launches shipped
- 50+
- launches shipped
- media placements
- 500+
- media placements
- founders on every account
- 2
- founders on every account
Press we've placed: Forbes · CoinDesk · Decrypt · Cointelegraph · The Block
Rahil Jain, Co-founder, Chalk Labs. Ex-Goldman Sachs engineer. You talk to the person who builds it.
Get automotive-hardware-safety running in your business
Tell us what you want to automate. A founder replies within one working day with a plan, not a pitch deck.
Cite this page
automotive-hardware-safety skill. Agent Mart. https://agentmart.dev/skills/pangzhenying2025-automotive-hardware-safety (last updated 2026-10-24)