hunt-ics
ICS/SCADA/OT exploitation - Modbus (502), S7comm (102), EtherNet/IP (44818), DNP3, OpenPLC, Node-RED SCADA, PLC/HMI/coil/holding-register attacks.
Skill by Encod3d-Sec
Install
Works with Claude Code, Claude apps, Codex, Cursor, Gemini CLI, GitHub Copilot, VS Code, OpenCode, Goose, Windsurf. Read the repository before you give any tool access to your data.
npx agentmarket install skill/encod3d-sec-hunt-ics
Asks which of your tools to add it to (Claude Code, Codex, Cursor, VS Code, Windsurf, Gemini CLI, Claude Desktop) and shows the change first. See https://agentmart.dev/cli.
Get the weekly diff
The weekly diff: one email a week with new agent tools, notable updates and grade changes, plus security alerts for tools you follow. Double opt-in, one-click unsubscribe.
About
Reviews
Write a reviewNo reviews yet. Installed it? Reviews come from verified installers only. How reviews work
Permissions
What this skill can do and what it asks for, from its SKILL.md. Checked Oct 25, 2026.
- Tools
- No tools found
- Secrets
- None asked for
- Install scripts
- None found
Network hosts it talks to 1
codeload.github.com· found in install command
Files it touches
~/.claude/skills/hunt-ics
What's inside
- Skill name
hunt-ics- Description
- ICS/SCADA/OT exploitation - Modbus (502), S7comm (102), EtherNet/IP (44818), DNP3, OpenPLC, Node-RED SCADA, PLC/HMI/coil/holding-register attacks. Use when a target exposes industrial protocols or the goal is to drive a plant to a dangerous state (over-pressure/over-speed/disable interlock) and read the flag the HMI/CCTV reveals.
- License
- MIT
- Instructions
- 75 lines in SKILL.md · view on GitHub
Files (1)
- SKILL.md
SKILL.md (first lines)
# Hunt: ICS / SCADA / OT
**Assumes `hunt-core`** for the scope gate, two-account rule, confirmation gate, enumeration limits, stop conditions, wiki protocol, FIND output, and Deadends. Do not re-derive any of that here.
## SAFETY - hard stop, overrides everything below
Writing to a live PLC moves real machinery: it can over-pressure a vessel, over-speed a motor, or disable a safety interlock, and so **damage equipment or injure and kill people**. Only ever drive a process toward a dangerous state on a target that is EXPLICITLY an authorized lab or CTF simulation. Never on a real plant, and never when scope carries `no_dos`/`passive_only` - there OT is READ-ONLY (FC1-4), never write (FC5/6/15/16). The instant the objective is met (e.g. the flag the HMI/CCTV reveals is in hand), STOP writing and revert any coil/register you changed if you can. This is a hard stop and it outranks every other note in this file.
## Wiki
```
qmd_query "ICS SCADA OT Modbus S7comm EtherNet/IP DNP3 OpenPLC Node-RED PLC HMI coil holding register" via wiki-search MCP
```
Hub: [[network-moc]] (live index). Primary page: [[ics-scada-modbus]]. Payload arsenal: `wiki/payloads/modbus.md`.
Anchors: [[iot-attacks]], [[firmware-hardware]].
## Attack surface (ranked by exploitation value)
1. **Modbus / TCP 502** - no auth, no session, trivially readable AND writable. The primary lever: FC1-4 read coils/registers, FC5/6/15/16 write them. Highest value, highest danger.
2. **OpenPLC web (8080)** and **Node-RED (1880, dashboard `/ui`)** - the SCADA/IT side that drives the PLC. OpenPLC routes `/programs /monitoring /hardware /users`; authed OpenPLC = upload-program RCE. Node-RED `/ui` socket.io config NAMES the registers.
3. **HMI web app** (Flask/Werkzeug with an `/api/...` live-state endpoint) - not itself the lever but the ORACLE that tells you whether a write landed.
4. **S7comm / TCP 102** (S7/iso-tsap) - `python-snap7` `db_read` for creds/flags in data blocks.
5. **EtherNet/IP 44818**, **DNP3 20000**, then **BACnet 47808/udp**, **Fox 1911/4911**, **OPC-UA 4840** - enumerate with the matching nmap scripts; less commonly the CTF lever, but map them.
## Methodology
1. **Recon**: `nmap -p- ...` then `nmap -Pn -p102,502,20000,44818 --script s7-info,modbus-discover,enip-info,dnp3-info $T`. Note the unit/slave id ("sid 0x1").
2. **Find the oracle**: the HMI `/api/state`-style endpoint (it reads the PLC and tells you live status). Node-RED `/ui` socket.io config NAMES the registers ("Read Pressure" = FC3 reg0). This is how you know a write landed.
3. **Enumerate Modbus** (raw socket, not pymodbus): dump FC1-4, **ASCII-decode registers** (creds/flags hide there), scan unit ids. Reads (FC1-4) are safe; this step never writes. See [[modbus]].
4. **Map process variables -> registers/coils**. The pressure/temp/level sensor is a holding/input register; pumps/valves/cooling/safety are coils.
5. **Drive to the danger state (authorized lab/CTF ONLY - see SAFETY)**: `FC6` over-drive the process variable to max (65535); then **defeat the safety/protection interlock** - a controller loop (cooling/relief/ESD) fights you, and it is usually ONE coil. Find it with a BOUNDED, one-write-at-a-time probe, NEVER a free-running write loop (hunt-core: never enumerate writes; this narrow, reverting, oracle-gated probe on an authorized simulation is the sole carve-out): write ONE coil (FC5), read the HMI oracle, and if the state did not flip toward the goal, write that coil back before trying the next. Cover coils 0-31 this way - the control coil is rarely at 0-5, so go wide but stay bounded. If nothing in 0-31 flips the interlock, that is a Deadend; do not widen indefinitely.
6. **Read the payoff**: HMI flips (e.g. "Explosion Detected!") and points the CCTV/HMI at new media. **The flag is frequently a VISUAL overlay** in that image/video - fetch it, `ffmpeg -i x.mp4 -vf fps=1 f_%02d.jpg`, and VIEW the frames (not strings/exif). Objective met -> stop writing (SAFETY).
7. **S7**: `python-snap7` `db_read` the data blocks (creds/flags). Banner-only sims (s7-info works but no DBs) = decoy.
8. **OpenPLC**: try `openplc:openplc`; if changed, do NOT grind the login - the protection is usually disabled directly over Modbus (a coil flag the ladder reads). Authed OpenPLC = upload-program RCE.
9. **Distill (when confirmed):** stage a GENERIC candidate - `python3 scripts/wiki-stage.py --kind technique --slug <slug> --target-page techniques/mobile-iot/ics-scada-modbus.md`.
## Chaining
- HMI / Node-RED web app -> read the `/api/state` oracle and the register NAMES -> know exactly which Modbus address is the process variable and which is the interlock, instead of guessing blind.
- OpenPLC authed (default `openplc:openplc`) -> upload-program RCE on the SCADA host -> shell, not just process control. Prefer disabling protection over unauthenticated Modbus first (cheaper, no login grind).
- Danger state reached -> the payoff media (CCTV/HMI overlay) -> flag. The Modbus write is the pivot; the flag is in the frame (step 6).
## Evasion
- Wrong **unit/slave id** looks like a dead PLC: if FC1-4 error out, scan unit ids (the `modbus-discover` "sid" value) before concluding the device is read-only or absent.
## Lessons (THM Kaboom)
- The challenge NARRATIVE is the literal solve ("over-pressure the pump -> blow-out", "disable the protection"). Map each phrase to a Modbus write before chasing web creds.
- Coils 0-5 were inert; the safety kill-switch was **coil 10** -> sweep WIDE (still bounded and reverting, per step 5).
- The OpenPLC login (`openplc:openplc` changed) was a rabbit hole that OOM'd the tooling host with a brute. Disable protection over Modbus instead.
- Flag was burned into the CCTV explosion video (`/video?mode=explodedflag23`), invisible to strings -> extract + view frames.
## Confirmation gate
**NOT confirmation:** a Modbus/S7/EtherNet-IP port open and banner-grabbed; a coil/register/data-block you can only READ; an FC1-4 dump that returns values; the HMI showing a value you did not change; a write (FC5/6/15/16) that returned an ACK with no observed state change. A readable register alone proves reachability, not control.
**IS confirmation (control/impact finding):** a coil/register you WROTE whose effect is observed on the oracle - the HMI / Node-RED live-state flips to the intended (danger) state, the simulated process variable moves, or the interlock is demonstrably defeated - reproduced on a clean connection, culminating in the payoff (the flag the HMI/CCTV reveals). No observed effect = no control finding; log it as reachability at most.
An unauthenticated READ of OT state is a valid lower-severity finding in its own right (confirmed by demonstrating the unauth read), but it is NOT a control or physical-impact claim - keep the two separate.
## Severity
| Demonstrated impact | Rating |
|---|---|
| Unauth write to a safety-critical coil/register - physical impact, ESD or interlock bypass | critical |
| Unauth process-variable write (no safety bypass) | high |
| Unauth read of OT state (registers/coils/data blocks) | medium |
## Deadends
```
Append: - [ ] ICS <host> -- <proto> read-only / sim-only; no writable control coil found (swept 0-31)
```
Record the range you swept and whether an oracle existed, so the next pass does not re-run the same bounded probe.From Encod3d-Sec/TORCH, MIT.
More from Encod3d-Sec/TORCH
- 0.741score
ingest
Encod3d-Sec
Synthesize raw recon/test output into engagement state.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
redteamlead
Encod3d-Sec
On-demand senior red-team lead advisor.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
campaign-health
Encod3d-Sec
Health check for the bb/pt/ctf workflow driver subsystem - verifies everything is in place so every machine runs the same.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
fuzz
Encod3d-Sec
Adaptive, targeted web fuzzing - deterministic wordlist selection (wl-pick.sh) plus judgment.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
learn
Encod3d-Sec
Post-engagement knowledge harvest AND harness retrospective - after a box/bugbounty/pentest/CTF is completed, first diff how the engagement was EXECUTED…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
metasploit
Encod3d-Sec
Drive msfconsole across the workflow - DB-backed recon (db_nmap, auxiliary scanners), version->exploit search/check/run, multi/handler reverse shells…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
hunt-windows
Encod3d-Sec
Local Windows privilege escalation on a STANDALONE / workgroup host, or a local shell on a domain member - foothold to SYSTEM.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
arsenal
Encod3d-Sec
Wiki-first "what do I use" lookup - pick the automated TOOL (wiki/tools/), then the PAYLOAD/technique (wiki/payloads/ + wiki/cheatsheets/), for a…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
coverage
Encod3d-Sec
Show per-asset vuln-class coverage gaps for the active engagement so nothing in scope is skipped.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
delegate
Encod3d-Sec
Autonomous sub-agent hand-off for a fiddly, fully-specified exploit-compile / escalation RUN - the main agent stays on strategy and the board while a cheap…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
hunt-idor
Encod3d-Sec
IDOR / BOLA hunting - two-account methodology, identifier discovery and UUID leak chaining, the trusted-identifier test, GraphQL node and nested-object IDOR…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
walkthrough
Encod3d-Sec
Assemble a report-ready walkthrough.md for a SOLVED engagement - populate the Evidence gallery from the poc/ images captured during the engagement, and draft…
SkillBFreshness: B★ 335Claude Code +9
Signals
- Stars
- 335
- Forks
- 49
- Open issues
- 0
- Last commit (this folder)
- Jul 27, 2026 (3 months ago)
From GitHub (fetched Oct 24, 2026).
Details
- License
- MIT
- Repository
- github.com/Encod3d-Sec/TORCH
- First seen
- Oct 24, 2026
- Last checked
- Oct 24, 2026
- Source
- GitHubgithub-graphql
More from Encod3d-Sec
- 0.741score
arsenal
Encod3d-Sec
Wiki-first "what do I use" lookup - pick the automated TOOL (wiki/tools/), then the PAYLOAD/technique (wiki/payloads/ + wiki/cheatsheets/), for a…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
coverage
Encod3d-Sec
Show per-asset vuln-class coverage gaps for the active engagement so nothing in scope is skipped.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
hunt-idor
Encod3d-Sec
IDOR / BOLA hunting - two-account methodology, identifier discovery and UUID leak chaining, the trusted-identifier test, GraphQL node and nested-object IDOR…
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
hunt-windows
Encod3d-Sec
Local Windows privilege escalation on a STANDALONE / workgroup host, or a local shell on a domain member - foothold to SYSTEM.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
campaign-health
Encod3d-Sec
Health check for the bb/pt/ctf workflow driver subsystem - verifies everything is in place so every machine runs the same.
SkillBFreshness: B★ 335Claude Code +9 - 0.741score
delegate
Encod3d-Sec
Autonomous sub-agent hand-off for a fiddly, fully-specified exploit-compile / escalation RUN - the main agent stays on strategy and the board while a cheap…
SkillBFreshness: B★ 335Claude Code +9
Cite this page
hunt-ics skill. Agent Mart. https://agentmart.dev/skills/encod3d-sec-hunt-ics (last updated 2026-10-24)