Skip to content
Agentmart
Submit a tool

Engineering

27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).

Connector by novtriq.tech · Domain verified by the MCP Registry

IndexedLicense unknownRemote (HTTP)
Write a review

Install

Works with Claude Code, VS Code, Cursor, Windsurf. Read the repository before you give any tool access to your data.

npx agentmarket install connector/novtriq-tech-engineering

Asks which of your tools to add it to (Claude Code, Codex, Cursor, VS Code, Windsurf, Gemini CLI, Claude Desktop) and shows the change first. See https://agentmart.dev/cli.

Remote endpoint

  • https://api.novtriq.tech/mcp Remote (HTTP)

Get the weekly diff

The weekly diff: one email a week with new agent tools, notable updates and grade changes, plus security alerts for tools you follow. Double opt-in, one-click unsubscribe.

We use your email only for this newsletter. Privacy

About

27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).

No reviews yet. Installed it? Reviews come from verified installers only. How reviews work

Permissions

What this server can do and what it asks for, from its tool list and install config. Checked Oct 25, 2026.

Tools
9 read · 2 write · 0 delete · 16 not yet classified
Secrets
None asked for
Install scripts
Nothing to install (hosted)
Runs as
Hosted (remote endpoint)

Tools by what they do 27

From the running server's own tool list (tools/list) on Oct 25, 2026.

Read 9 · Look things up without changing anything.

  • assess_epbd_score
  • calculate_carbon
  • calculate_pue
  • check_grid_feasibility_uae
  • check_nis2_readiness
  • check_uae_bim_compliance
  • check_uae_cybersecurity
  • estimate_cooling_load
  • get_technical_dd_quote

Write 2 · Create, change, send or run things.

  • building_carbon_footprint
  • building_readiness

Not yet classified 16 · We could not tell from the name and description.

  • contractor_vetting
  • dgnb_bim_readiness
  • digital_renovation_passport
  • eed_datacentre_pack
  • eu_cost_benchmarking
  • eurocode_beam_designer
  • eurocode_column_checker
  • heatpump_heatloss
  • mees_checker
  • part_o_overheating
  • part_s_ev
  • roi_calculator
Show 4 more tools
  • sap_sbem_precheck
  • thermal_load
  • uae_climate_ghg
  • uk_planning_checker

Network hosts it talks to 1

  • api.novtriq.tech · found in remote endpoint, install command

Files it touches

  • Any path the agent passes to its tools

Tools (27)

As the server listed them on Oct 25, 2026. Descriptions are the server’s own words; hidden characters are shown as [U+…].

  • assess_epbd_score

    Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures.

  • building_carbon_footprint

    Building carbon footprint (Scope 1/2/3) with CRREM stranding check and embodied carbon. Returns per-scope tCO2e, intensity, CRREM compliance, net-zero gap and priority actions.

  • building_readiness

    Building Readiness assessment for change-of-use / conversion. Returns a 0-100 readiness score, project complexity, four domain scores (structural, MEP, compliance, digital/BIM) with RAG, and recommendations.

  • calculate_carbon

    Calculate operational + embodied carbon and net-zero gap (CIBSE TM65 / RICS WLCA). Returns carbon intensity, benchmark, and prioritised reduction measures with payback.

  • calculate_pue

    Calculate Power Usage Effectiveness (PUE) for a data centre or server room. Returns PUE score, efficiency rating, annual cost estimate, and engineering recommendations.

  • check_grid_feasibility_uae

    Assess UAE grid connection feasibility (DEWA/ADDC/SEWA/FEWA). Returns feasibility score, connection timeline, recommended voltage, substation requirement, and next steps.

  • check_nis2_readiness

    Assess NIS2 Directive (EU 2022/2555) compliance readiness. Returns compliance score (0-18), maturity level, estimated fine exposure, and prioritised remediation actions.

  • check_uae_bim_compliance

    Check UAE BIM mandate applicability (Dubai Circular 196, Abu Dhabi DMT, Sharjah). Returns mandate status, compliance score, required LOD, and submission checklist.

  • check_uae_cybersecurity

    Assess UAE cybersecurity regulatory compliance (NESA IAS, Dubai ISR, CBUAE, TDRA). Returns applicable framework, compliance score, critical gaps, and mandatory controls.

  • contractor_vetting

    NIS2 / EPBD contractor vetting score from a 12-question checklist across financial, technical, cyber (NIS2) and energy (EPBD) categories. Flags blocking (critical) failures and returns recommended additional checks. Not a formal due-diligence report.

  • dgnb_bim_readiness

    DGNB certification pre-score and BIM (ISO 19650) maturity self-assessment from a 20-question checklist. Returns pre-score, achievable certification level, BIM level, domain breakdown and prioritised gaps. Not a formal DGNB audit.

  • digital_renovation_passport

    EPBD-style staged digital renovation passport: 3-phase roadmap (quick wins, system upgrades, deep renovation) with cost ranges, energy savings and EPC trajectory from current EPC, floor area and heating type. Indicative.

  • eed_datacentre_pack

    EU Energy Efficiency Directive data-centre reporting pack (Dir (EU) 2023/1791 Art.12 + Del. Reg (EU) 2024/1364). Determines reporting scope (IT power >= 500 kW) and computes the mandated KPIs PUE, WUE, ERF and REF. Note: the regulation mandates reporting, not target values.

  • estimate_cooling_load

    Estimate cooling load using CIBSE Guide B2 / ASHRAE methodology. Returns required capacity, installed capacity with redundancy, system recommendation, and annual energy.

  • eu_cost_benchmarking

    Parametric construction cost benchmark across UK/EU/GCC by country, project type, specification, procurement, programme and BIM. Returns per-m2 and total cost ranges plus a cost breakdown. Indicative parametric estimate, validate against current cost indices.

Show 12 more tools
  • eurocode_beam_designer

    Preliminary Eurocode beam design (steel EC3 / composite / reinforced concrete EC2). Selects a section, computes ULS bending & shear utilisation, SLS deflection, and fire protection. Indicative, not a stamped design.

  • eurocode_column_checker

    Eurocode axial column buckling check (steel EC3 6.3.1 flexural buckling / RC EC2 5.8 simplified). Returns Ncr, non-dimensional slenderness, reduction factor chi, NRd and utilisation. Indicative, not a stamped design.

  • get_technical_dd_quote

    Generate an indicative Technical Due Diligence (TDD) fee estimate. Returns preliminary and full DD fee ranges (GBP), turnaround days, and contact CTA.

  • heatpump_heatloss

    Domestic whole-dwelling fabric + ventilation heat-loss estimate for heat pump sizing (BS EN 12831 / MCS), from floor area, storeys, age band, location and glazing. Returns design heat loss (kW), recommended heat pump output, indicative SCOP and annual demand. Typical U-values/SCOP, not measured.

  • mees_checker

    England & Wales Minimum Energy Efficiency Standard (MEES) check for private rented property. Tests against the in-force EPC E minimum (domestic and non-domestic) and surfaces the PROPOSED (not yet law) EPC C / 2030 uplift as an advisory only. Returns compliance, can-let, cost cap and penalties.

  • part_o_overheating

    UK Approved Document O 2021 simplified-method overheating check for new residential: tests maximum glazing area (by orientation, risk zone, cross vs single aspect) and minimum free ventilation area. Returns pass/fail and points to CIBSE TM59 modelling if it fails. Indicative.

  • part_s_ev

    UK Approved Document S 2021 electric-vehicle charge-point requirement calculator for new build and major renovation, residential and non-residential. Returns required charge points, cable routes (1-in-5 for non-residential), minimum power and the applicable cost caps/exemptions. Indicative.

  • roi_calculator

    Engineering ROI calculator. Returns current manual cost, annual saving, net benefit, ROI %, payback months, 3-year NPV and a verdict.

  • sap_sbem_precheck

    UK SAP 10.3 / SBEM EPC precheck. Maps a known SAP rating (1-100) to its EPC band, and/or computes annual CO2 and primary energy from fuel consumption using validated SAP 10 fuel factors. The official EPC band is cost-based and needs a full SAP/RdSAP assessment.

  • thermal_load

    Thermal Load Estimator for data centres / critical facilities. Returns total heat load, cooling capacity, units, airflow, chiller size, PUE estimate, power density, and a CRAC/CRAH/DLC/immersion comparison.

  • uae_climate_ghg

    UAE Scope 1 + Scope 2 GHG estimate from electricity and gas use, with emirate-specific grid emission factors (Dubai/Abu Dhabi/national) and the Federal Decree-Law No. 11 of 2024 mandatory-reporting context. Grid factors carry base-year/confidence caveats.

  • uk_planning_checker

    UK permitted-development (GPDO 2015, England) rules engine for extensions, loft conversions and change of use. Returns a verdict (likely_pd / requires_permission / complex), applicable PD class, conditions and flags (listed building, Article 4, conservation area, AONB). Indicative, verify with the LPA.

Signals

Last release
Jul 26, 2026 (3 months ago)

Details

Registry name
tech.novtriq/engineering
Version
1.0.0
Auth
Auth not stated
License
License unknown
First seen
Oct 24, 2026
Last checked
Oct 24, 2026
Cite this page

Engineering MCP server. Agent Mart. https://agentmart.dev/connectors/novtriq-tech-engineering (last updated 2026-10-24)